DSC PC5010 / Power 832 Wiring

Power 832 Pc5010
  1. DSC PC5010 / Power 832 Trouble. View Trouble – Press. 2 and a zone light will turn on showing trouble. Zone light 1 = Indicates Service Required, press 1 again to.
  2. The DSC Power 832, also known as Model PC5010 has been one of the most popular DSC security products for years. It is inexpensive, feature-packed, and versatile, which has made it a popular choice for DIY alarm systems. It’s also the system I chose for my own home, and I’ll tell you why in a minute.

View and Download DSC Power832 PC5010 instruction manual online. Power832 PC5010 security system pdf manual download. How to reset DSC power 832 PC5010 to default installer code 5010 master code 1234.

Zones 32 Hardwired or Wireless zones
Batteries
Main Panel 12 volt rechargeable Gel-Cell inside main panel
Door/Windows 3 to 4 AAA Alkaline
Motion Sensor 4 AAA Alkaline
Smoke Detector 6 AA Alkaline
4-button Keyfob Button type batteries (LR44)
Pendant Panic Non-Replaceable
Downloadable Yes, press * + 6 + Master Code + 3 + to Send Panel
Panic Buttons Police, Fire and Medical
Arming on Residential systems can only be done with AWAY or STAY keys
Arming on Commercial systems may be done with AWAY or STAY + User Code
Arm Away Hold AWAY for 3 seconds (ARM light turns ON)
Arm Stay Hold STAY for 3 seconds (ARM and BYPASS lights turn ON)
Instant Arm Arm the System then press * 9 Arm light will begin to flash
Disarm 4-digit User Code (Press # if any mistake is made)
Silence Alarm 4-digit User Code (Press CLEAR to stop any keypad flashing)
Bypass 1. Press * 1 (BYPASS Light should begin flashing)
2. Press Zone (01 to 32) (Zone light should turn ON)
3. Press # to exit
(If this does not work try * 1 + Master Code + (01 to 32) + # )
Reset Smoke * + 7 2 (Or * + 7 1, * + 7 2 is more common, if smoke detector continues to sound power down system)
CLEAR Key Clears Memory light
EXIT Key Press to leave without disarming
(system will arm doors when closed again)
Door Chimes Hold CHIME key for 3 seconds to turn On/Off
Alarm Memory * 3 to view last alarm or for LCD keypads see below
LCD
Event Buffer
1. Press * 6 + Master Code
2. Press < or > keys to scroll to “Event Buffer”, press *
3. Use < key to move forward in time, > key moves back in time
4. Press * to toggle between Time/Date of Event and what Event was
Examples: Closing by User 40 = Master Code Armed System
Opening by User 01 = User 01 Disarmed system
Zone Fault Zone 24 = Zone 24 is in trouble
Sensor Test None, Arm system then trip sensors
(Wireless motions require no movement for 4 minutes prior to testing)
Siren Test * 6 + Master Code + 4
System Clock * 6 + Master Code + 1 and enter time (1PM 11/26/99 is 1300112699) end with #
Keypad Volume Hold * until desired volume is found
Enable
Download
* 6 + Master Code + 5 #

Top of
Page
Need help? Call 1-800-677-82781-800-677-82781-800-677-8278
Compare Now
Product Review for Duracell Ultra ADT DSC Power 832 Security 7AH AGM Battery with F1 Terminals
  • Trusted Duracell Ultra Power backed by a 12-month warranty
  • For backup or cycling applications
  • Fits these applications: emergency lighting, UPS backups, data centers and fire & security
  • Volume Discounts Available!
Voltage: 12
Capacity: 7AH
Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Compare Now

Dsc Pc5010 User Manual

Product Review for Duracell Ultra ADT DSC Power 832 Security 8AH AGM Battery with F1 Terminals
  • Trusted Duracell Ultra Power backed by a 12-month warranty
  • Fully compatible replacement for a 7AH battery, but with an 11% longer runtime
  • Fits these applications: emergency lighting, data centers, UPS systems, backup & cycling applications and fire & security
  • Volume Discounts Available!
Voltage: 12
Pc5010
Capacity: 8AH
Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Compare Now
Product Review for Duracell Ultra 12V SLA Sealed Lead Acid 9AH General Purpose Battery
  • Trusted Duracell Ultra power backed by a 12-month warranty
  • Fits these applications: emergency lighting, UPS backups, data centers and fire & security
  • Fully compatible replacement for a 7Ah battery, but with a 13% longer runtime
  • Volume Discounts Available!
Voltage: 12
Capacity: 9AH
Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Compare Now
Product Review for Power Sonic ADT DSC Power 832 Security 7AH AGM Battery with F1 Terminals
  • Power Sonic branded SLA with 1-year warranty
  • Absorbent Glass Mat (AGM) technology provides superior performance
  • Valve regulated, maintenance-free spill proof construction
Voltage: 12
Power 832 Pc5010
Capacity: 7AH
Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Compare Now
Product Review for Duracell Ultra ADT DSC Power 832 Security 7AH Deep Cycle AGM BatteryPc5010
  • Trusted Duracell Ultra power backed by 12-month warranty
  • Deep cycle capacity 7Ah
  • Absorbent Glass Mat (AGM) technology privdes superior performance.
Voltage: 12
Capacity: 7AH
Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Dsc Power 832 Pc5010 Battery Replacement

Help is just a phone call away! 1-800-677-82781-800-677-8278

Dsc Power 832 Pc5010 Troubleshooting

We strive to provide the best price available on BatteriesPlus.com and in our stores. Store pricing may vary from the price advertised on BatteriesPlus.com. Fees may apply for recycling, environmental disposal, and/or labor/installation.

Shop
Categories

About Us

Product
Support

Our Policies

All registered trademarks are the property of their respective owners.
Copyright ©2020, Batteries Plus LLC. All rights reserved.
Duracell is a registered trademark of Duracell U.S. Operations, Inc., used under license. All rights reserved.

(0 items)